    Image fusion of LM-MRI and MRA for endovascular interventions

    Get PDF
    Peripheral arterial occlusive disease can be treated with endovascular interventions. These interventions are currently intraoperatively guided by fluoroscopy. A possible alternative is LF-MRI, but the current image quality of low-field (LF) MRI may not be sufficient. The purpose of this study is to evaluate the possibility of image fusion of LF-MRI with preoperative MRA to improve the image quality. To test this, LF-MRI and 3T MRI images were made of a healthy test subject. These images were registrated using manual landmark detection. The result was a visually successful registration image of LF-MRI and anatomical MRI, which shows the possibility of manual image registration

    Investigating the potential of low concentrations of iron-oxide contrast agents at low magnetic field strengths for the purpose of MR guided interventions

    Get PDF
    Iron-oxide contrast agents might prove valuable in endovascular interventions at low-field MRI because their relaxivities are more favorable at lower field strengths, but still maintaining and generating positive contrast. Differences between a range concentrations of a gadolinium-based and a super paramagnetic iron-oxide (SPIO) contrast agent were compared both in simulations and experimentally on 0.25T using three different MR sequences. Optimal contrast for all sequences was found around 0.15mM for the SPIO agent and for concentrations higher than 7.0mM for the gadolinium agent. The use of low concentration SPIOs therefore is more beneficial for imaging at low magnetic field strengths than gadolinium-based contrast agents

    Internal Jugular Vein Geometry Under Multiple Inclination Angles with 3D Low-Field MRI in Healthy Volunteers

    Get PDF
    BACKGROUND: Cerebral venous pathways are subjected to geometrical and patency changes due to body position. The internal jugular veins (IJVs) are the main venous drainage pathway in supine position. Their patency and geometry should be evaluated under different body inclination angles over a three‐dimensional (3D) volume in the healthy situation to better understand pathological cases. PURPOSE: To investigate whether positional changes in the body can affect the geometrical properties and patency of the venous system. STUDY TYPE: Prospective. POPULATION: 15 healthy volunteers, of which seven males and median age 22 years in a range of 19–59. FIELD STRENGTH/SEQUENCE: A 0.25‐T tiltable MRI system was used to scan volunteers in 90° (sitting position), 69°, 45°, 21°, and 0° (supine position) in the transverse plane with the top at vertebra C2. A gradient echo sequence was used. ASSESSMENT: Three observers assessed IJVs on patency and created automatic centerlines from which diameter and patency were analysed perpendicular to the vessel at every 4 mm starting at the level of C2. STATISTICAL TESTS: A Student's t test was used to find statistical difference (p < 0.05) in average IJV diameters per inclination angle. RESULTS: The amount of fully collapsed IJVs increased from 33% to 93% (left IJV) and 14% to 80% (right IJV) when increasing the inclination angle from 0° to 90°. In both IJVs, the mean diameter (±SD) of the open vessels was significantly higher at 0° than 90° with 6.3 ± 0.5 mm vs. 4.4 ± 0.1 mm (left IJV) and 6.6 ± 0.6 mm vs. 4.3 ± 0.4 mm (right IJV). DATA CONCLUSION: Tiltable low‐field MRI can be used to assess IJV geometry and its associated venous pathways in 3D under multiple inclination angles. Next to a higher amount of collapsed vessels, the average diameter of noncollapsed vessels decreases with increasing inclination angles for both left and right IJVs. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE:

    A Multimodality Myocardial Perfusion Phantom:Initial Quantitative Imaging Results

    Get PDF
    This proof-of-concept study explores the multimodal application of a dedicated cardiac flow phantom for ground truth contrast measurements in dynamic myocardial perfusion imaging with CT, PET/CT, and MRI. A 3D-printed cardiac flow phantom and flow circuit mimics the shape of the left ventricular cavity (LVC) and three myocardial regions. The regions are filled with tissue-mimicking materials and the flow circuit regulates and measures contrast flow through LVC and myocardial regions. Normal tissue perfusion and perfusion deficits were simulated. Phantom measurements in PET/CT, CT, and MRI were evaluated with clinically used hardware and software. The reference arterial input flow was 4.0 L/min and myocardial flow 80 mL/min, corresponding to myocardial blood flow (MBF) of 1.6 mL/g/min. The phantom demonstrated successful completion of all processes involved in quantitative, multimodal myocardial perfusion imaging (MPI) applications. Contrast kinetics in time intensity curves were in line with expectations for a mimicked perfusion deficit (38 s vs. 32 s in normal tissue). Derived MBF in PET/CT and CT led to under- and overestimation of reference flow of 0.9 mL/g/min and 4.5 mL/g/min, respectively. Simulated perfusion deficit (0.8 mL/g/min) in CT resulted in MBF of 2.8 mL/g/min. We successfully performed initial, quantitative perfusion measurements with a dedicated phantom setup utilizing clinical hardware and software. These results showcase the multimodal phantom’s potential

    A Multimodality Myocardial Perfusion Phantom:Initial Quantitative Imaging Results

    Get PDF
    This proof-of-concept study explores the multimodal application of a dedicated cardiac flow phantom for ground truth contrast measurements in dynamic myocardial perfusion imaging with CT, PET/CT, and MRI. A 3D-printed cardiac flow phantom and flow circuit mimics the shape of the left ventricular cavity (LVC) and three myocardial regions. The regions are filled with tissue-mimicking materials and the flow circuit regulates and measures contrast flow through LVC and myocardial regions. Normal tissue perfusion and perfusion deficits were simulated. Phantom measurements in PET/CT, CT, and MRI were evaluated with clinically used hardware and software. The reference arterial input flow was 4.0 L/min and myocardial flow 80 mL/min, corresponding to myocardial blood flow (MBF) of 1.6 mL/g/min. The phantom demonstrated successful completion of all processes involved in quantitative, multimodal myocardial perfusion imaging (MPI) applications. Contrast kinetics in time intensity curves were in line with expectations for a mimicked perfusion deficit (38 s vs. 32 s in normal tissue). Derived MBF in PET/CT and CT led to under- and overestimation of reference flow of 0.9 mL/g/min and 4.5 mL/g/min, respectively. Simulated perfusion deficit (0.8 mL/g/min) in CT resulted in MBF of 2.8 mL/g/min. We successfully performed initial, quantitative perfusion measurements with a dedicated phantom setup utilizing clinical hardware and software. These results showcase the multimodal phantom’s potential.</p

    Commissioning and performance of the CMS pixel tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published verion of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3–4 microns RMS in the barrel and 3–14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)